Features |
Specifications |
Signaling protocol support |
Session Initiation Protocol (SIP) |
Full lines supported |
● 6861: 4 lines (SIP registrations)
|
Language support |
● English (American)
● English (United Kingdom)
|
Multiple ring tones |
● The phones support user-adjustable ring tones
|
Quality-of-Service (QoS) options |
● The phone supports Cisco Discovery Protocol and 802.1Q/p standards, and can be configured with an 801.1Q VLAN header containing the VLAN ID overrides configured by the admin VLAN ID
|
Security |
● 802.1X authentication
● Device authentication
● Encrypted configuration files
● File authentication
● Image authentication
● Manufacture-Installed Certificates
● Media encryption using SRTP with Advanced Encryption Standard AES-128 or AES-256
● Signaling encryption using TLS with AES-128 or AES-256
|
Configuration options |
● The user can configure the IP address assignment statically or through the DHCP client
|
Physical dimensions (HxWxD) |
● 6861: 8.2 x 8.1 x 1.3 in. (207 x 206 x 33 mm) (excluding foot stand)
|
Weight |
● 6861: 21 oz. (602.8 g) (excluding foot stand, handset, and package), 23.6 oz (670 g)) (including foot stand, excluding handset and package)
|
Display |
● 6861: 3.2 in. (8.1 cm), 320x120 pixels
|
Ethernet switch |
● 6861: A 10/100BASE-T Ethernet connection through one RJ-45 port for the LAN connection
|
Phone and KEM casing composition |
● Polycarbonate Acrylonitrile Butadiene Styrene (ABS) textured plastic
|
Power requirements |
● 6800 Key Expansion Module: No local power supply. The KEM receives power from the attached 6851 IP phone. The attached 6851 IP phone may be powered via PoE or the 6800 (5V) power adapter
|
Operational temperature |
● 32° to 104°F (0° to 40°C)
|
Nonoperational temperature shock |
● 14° to 140°F (-10° to 60°C)
|
Humidity |
● Operating 10% to 90%, noncondensing
● Non-operating 10% to 95%, noncondensing
|
Certification and compliance for 6821 |
● Regulatory compliance:
◦ CE Markings per directives 2014/30/EU and 2014/35/EU
● Safety:
◦ UL 60950 Second Edition
◦ CAN/CSA-C22.2 No. 60950 Second Edition
◦ EN 60950 Second Edition (including A11 and A12)
◦ IEC 60950 Second Edition (including A11 and A12)
◦ AS/NZS 60950
● EMC – Emissions
◦ 47CFR Part 15 (CFR 47) Class B
◦ AS/NZS CISPR32:2015 Class B
◦ CISPR 32: 2015_COR1:2016 Class B
◦ EN55032: 2015+AC:2016
◦ ICES003 Class B
◦ EN61000-3-2:2014 and IEC 61000-3-2:2014
◦ EN61000-3-3:2013 and IEC61000-3-3:2013
◦ VCCI Class B
● EMC – Immunity
◦ EN55024
◦ CISPR24
◦ Armadillo Light
● Telecom
◦ FCC Part 68 HAC
◦ CS-03-HAC
◦ AS/ACIF S004
◦ AS/ACIF S040
◦ NZ PTC 220
◦ Industry standards: TIA 810
● Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af
|
Certification and compliance for 6841, 6851, 6861 and 6871 |
● Regulatory compliance:
◦ CE Markings per directives 2004/108/EC and 2014/30/EU
● Safety:
◦ UL 60950 Second Edition
◦ CAN/CSA-C22.2 No. 60950 Second Edition
◦ EN 60950 Second Edition (including A11 and A12)
◦ IEC 60950 Second Edition (including A11 and A12)
◦ AS/NZS 60950
● EMC – Emissions
◦ 47CFR Part 15 (CFR 47) Class B
◦ AS/NZS CISPR32:2015 Class B
◦ CISPR 32: 2015_COR1:2016 Class B
◦ EN55032: 2015+AC:2016
◦ ICES003 Class B
◦ EN61000-3-2:2014 and IEC 61000-3-2:2014
◦ EN61000-3-3:2013 and IEC61000-3-3:2013
● EMC – Immunity
◦ EN55024
◦ CISPR24
◦ Armadillo Light
● Telecom
◦ FCC Part 68 HAC
◦ CS-03-HAC
◦ AS/ACIF S004
◦ AS/ACIF S040
◦ NZ PTC 220
◦ Industry standards: TIA 810 and TIA 920
● Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af (for CP-6851 only)
● Radio (for CP-6861 only)
◦ FCC Part 15
◦ EN 300.328
◦ EN 301-489-1
◦ EN 301-489-17
◦ EN 301-489-3
◦ NCC LP0002
◦ EN 301 893
◦ EN 300 330
◦ RSP-100-11
◦ RSS- Gen
◦ RSS-102
◦ RSS-210
◦ RSS-247-2
|
Features |
Specifications |
Signaling protocol support |
Session Initiation Protocol (SIP) |
Full lines supported |
● 6861: 4 lines (SIP registrations)
|
Language support |
● English (American)
● English (United Kingdom)
|
Multiple ring tones |
● The phones support user-adjustable ring tones
|
Quality-of-Service (QoS) options |
● The phone supports Cisco Discovery Protocol and 802.1Q/p standards, and can be configured with an 801.1Q VLAN header containing the VLAN ID overrides configured by the admin VLAN ID
|
Security |
● 802.1X authentication
● Device authentication
● Encrypted configuration files
● File authentication
● Image authentication
● Manufacture-Installed Certificates
● Media encryption using SRTP with Advanced Encryption Standard AES-128 or AES-256
● Signaling encryption using TLS with AES-128 or AES-256
|
Configuration options |
● The user can configure the IP address assignment statically or through the DHCP client
|
Physical dimensions (HxWxD) |
● 6861: 8.2 x 8.1 x 1.3 in. (207 x 206 x 33 mm) (excluding foot stand)
|
Weight |
● 6861: 21 oz. (602.8 g) (excluding foot stand, handset, and package), 23.6 oz (670 g)) (including foot stand, excluding handset and package)
|
Display |
● 6861: 3.2 in. (8.1 cm), 320x120 pixels
|
Ethernet switch |
● 6861: A 10/100BASE-T Ethernet connection through one RJ-45 port for the LAN connection
|
Phone and KEM casing composition |
● Polycarbonate Acrylonitrile Butadiene Styrene (ABS) textured plastic
|
Power requirements |
● 6800 Key Expansion Module: No local power supply. The KEM receives power from the attached 6851 IP phone. The attached 6851 IP phone may be powered via PoE or the 6800 (5V) power adapter
|
Operational temperature |
● 32° to 104°F (0° to 40°C)
|
Nonoperational temperature shock |
● 14° to 140°F (-10° to 60°C)
|
Humidity |
● Operating 10% to 90%, noncondensing
● Non-operating 10% to 95%, noncondensing
|
Certification and compliance for 6821 |
● Regulatory compliance:
◦ CE Markings per directives 2014/30/EU and 2014/35/EU
● Safety:
◦ UL 60950 Second Edition
◦ CAN/CSA-C22.2 No. 60950 Second Edition
◦ EN 60950 Second Edition (including A11 and A12)
◦ IEC 60950 Second Edition (including A11 and A12)
◦ AS/NZS 60950
● EMC – Emissions
◦ 47CFR Part 15 (CFR 47) Class B
◦ AS/NZS CISPR32:2015 Class B
◦ CISPR 32: 2015_COR1:2016 Class B
◦ EN55032: 2015+AC:2016
◦ ICES003 Class B
◦ EN61000-3-2:2014 and IEC 61000-3-2:2014
◦ EN61000-3-3:2013 and IEC61000-3-3:2013
◦ VCCI Class B
● EMC – Immunity
◦ EN55024
◦ CISPR24
◦ Armadillo Light
● Telecom
◦ FCC Part 68 HAC
◦ CS-03-HAC
◦ AS/ACIF S004
◦ AS/ACIF S040
◦ NZ PTC 220
◦ Industry standards: TIA 810
● Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af
|
Certification and compliance for 6841, 6851, 6861 and 6871 |
● Regulatory compliance:
◦ CE Markings per directives 2004/108/EC and 2014/30/EU
● Safety:
◦ UL 60950 Second Edition
◦ CAN/CSA-C22.2 No. 60950 Second Edition
◦ EN 60950 Second Edition (including A11 and A12)
◦ IEC 60950 Second Edition (including A11 and A12)
◦ AS/NZS 60950
● EMC – Emissions
◦ 47CFR Part 15 (CFR 47) Class B
◦ AS/NZS CISPR32:2015 Class B
◦ CISPR 32: 2015_COR1:2016 Class B
◦ EN55032: 2015+AC:2016
◦ ICES003 Class B
◦ EN61000-3-2:2014 and IEC 61000-3-2:2014
◦ EN61000-3-3:2013 and IEC61000-3-3:2013
● EMC – Immunity
◦ EN55024
◦ CISPR24
◦ Armadillo Light
● Telecom
◦ FCC Part 68 HAC
◦ CS-03-HAC
◦ AS/ACIF S004
◦ AS/ACIF S040
◦ NZ PTC 220
◦ Industry standards: TIA 810 and TIA 920
● Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af (for CP-6851 only)
● Radio (for CP-6861 only)
◦ FCC Part 15
◦ EN 300.328
◦ EN 301-489-1
◦ EN 301-489-17
◦ EN 301-489-3
◦ NCC LP0002
◦ EN 301 893
◦ EN 300 330
◦ RSP-100-11
◦ RSS- Gen
◦ RSS-102
◦ RSS-210
◦ RSS-247-2
|