Skip to content
Skip to product information
Description

Features

Specifications

Signaling protocol support

Session Initiation Protocol (SIP)

Full lines supported


●  6861: 4 lines (SIP registrations)

Language support


●  English (American)
●  English (United Kingdom)

Multiple ring tones

●  The phones support user-adjustable ring tones

Quality-of-Service (QoS) options

●  The phone supports Cisco Discovery Protocol and 802.1Q/p standards, and can be configured with an 801.1Q VLAN header containing the VLAN ID overrides configured by the admin VLAN ID

Security

●  802.1X authentication
●  Device authentication
●  Encrypted configuration files
●  File authentication
●  Image authentication
●  Manufacture-Installed Certificates
●  Media encryption using SRTP with Advanced Encryption Standard AES-128 or AES-256
●  Signaling encryption using TLS with AES-128 or AES-256

Configuration options

●  The user can configure the IP address assignment statically or through the DHCP client

Physical dimensions (HxWxD)


●  6861: 8.2 x 8.1 x 1.3 in. (207 x 206 x 33 mm) (excluding foot stand)

Weight


●  6861: 21 oz. (602.8 g) (excluding foot stand, handset, and package), 23.6 oz (670 g)) (including foot stand, excluding handset and package)

Display


●  6861: 3.2 in. (8.1 cm), 320x120 pixels

Ethernet switch


●  6861: A 10/100BASE-T Ethernet connection through one RJ-45 port for the LAN connection

Phone and KEM casing composition

●  Polycarbonate Acrylonitrile Butadiene Styrene (ABS) textured plastic

Power requirements


●  6800 Key Expansion Module: No local power supply. The KEM receives power from the attached 6851 IP phone. The attached 6851 IP phone may be powered via PoE or the 6800 (5V) power adapter

Operational temperature

●  32° to 104°F (0° to 40°C)

Nonoperational temperature shock

●  14° to 140°F (-10° to 60°C)

Humidity

●  Operating 10% to 90%, noncondensing
●  Non-operating 10% to 95%, noncondensing

Certification and compliance for 6821

●  Regulatory compliance:
◦  CE Markings per directives 2014/30/EU and 2014/35/EU
●  Safety:
◦  UL 60950 Second Edition
◦  CAN/CSA-C22.2 No. 60950 Second Edition
◦  EN 60950 Second Edition (including A11 and A12)
◦  IEC 60950 Second Edition (including A11 and A12)
◦  AS/NZS 60950
●  EMC – Emissions
◦  47CFR Part 15 (CFR 47) Class B
◦  AS/NZS CISPR32:2015 Class B
◦  CISPR 32: 2015_COR1:2016 Class B
◦  EN55032: 2015+AC:2016
◦  ICES003 Class B
◦  EN61000-3-2:2014 and IEC 61000-3-2:2014
◦  EN61000-3-3:2013 and IEC61000-3-3:2013
◦  VCCI Class B
●  EMC – Immunity
◦  EN55024
◦  CISPR24
◦  Armadillo Light
●  Telecom
◦  FCC Part 68 HAC
◦  CS-03-HAC
◦  AS/ACIF S004
◦  AS/ACIF S040
◦  NZ PTC 220
◦  Industry standards: TIA 810
●  Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af

Certification and compliance for 6841, 6851, 6861 and 6871

●  Regulatory compliance:
◦  CE Markings per directives 2004/108/EC and 2014/30/EU
●  Safety:
◦  UL 60950 Second Edition
◦  CAN/CSA-C22.2 No. 60950 Second Edition
◦  EN 60950 Second Edition (including A11 and A12)
◦  IEC 60950 Second Edition (including A11 and A12)
◦  AS/NZS 60950
●  EMC – Emissions
◦  47CFR Part 15 (CFR 47) Class B
◦  AS/NZS CISPR32:2015 Class B
◦  CISPR 32: 2015_COR1:2016 Class B
◦  EN55032: 2015+AC:2016
◦  ICES003 Class B
◦  EN61000-3-2:2014 and IEC 61000-3-2:2014
◦  EN61000-3-3:2013 and IEC61000-3-3:2013
●  EMC – Immunity
◦  EN55024
◦  CISPR24
◦  Armadillo Light
●  Telecom
◦  FCC Part 68 HAC
◦  CS-03-HAC
◦  AS/ACIF S004
◦  AS/ACIF S040
◦  NZ PTC 220
◦  Industry standards: TIA 810 and TIA 920
●  Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af (for CP-6851 only)
●  Radio (for CP-6861 only)
◦  FCC Part 15
◦  EN 300.328
◦  EN 301-489-1
◦  EN 301-489-17
◦  EN 301-489-3
◦  NCC LP0002
◦  EN 301 893
◦  EN 300 330
◦  RSP-100-11
◦  RSS- Gen
◦  RSS-102
◦  RSS-210
◦  RSS-247-2

Cisco CP-6861-3PW-NA-K9= IP Phone Price in Dubai, UAE

CP-6861-3PW-NA-K9=

  • Cisco IP Phone 6800 Series
Description

Features

Specifications

Signaling protocol support

Session Initiation Protocol (SIP)

Full lines supported


●  6861: 4 lines (SIP registrations)

Language support


●  English (American)
●  English (United Kingdom)

Multiple ring tones

●  The phones support user-adjustable ring tones

Quality-of-Service (QoS) options

●  The phone supports Cisco Discovery Protocol and 802.1Q/p standards, and can be configured with an 801.1Q VLAN header containing the VLAN ID overrides configured by the admin VLAN ID

Security

●  802.1X authentication
●  Device authentication
●  Encrypted configuration files
●  File authentication
●  Image authentication
●  Manufacture-Installed Certificates
●  Media encryption using SRTP with Advanced Encryption Standard AES-128 or AES-256
●  Signaling encryption using TLS with AES-128 or AES-256

Configuration options

●  The user can configure the IP address assignment statically or through the DHCP client

Physical dimensions (HxWxD)


●  6861: 8.2 x 8.1 x 1.3 in. (207 x 206 x 33 mm) (excluding foot stand)

Weight


●  6861: 21 oz. (602.8 g) (excluding foot stand, handset, and package), 23.6 oz (670 g)) (including foot stand, excluding handset and package)

Display


●  6861: 3.2 in. (8.1 cm), 320x120 pixels

Ethernet switch


●  6861: A 10/100BASE-T Ethernet connection through one RJ-45 port for the LAN connection

Phone and KEM casing composition

●  Polycarbonate Acrylonitrile Butadiene Styrene (ABS) textured plastic

Power requirements


●  6800 Key Expansion Module: No local power supply. The KEM receives power from the attached 6851 IP phone. The attached 6851 IP phone may be powered via PoE or the 6800 (5V) power adapter

Operational temperature

●  32° to 104°F (0° to 40°C)

Nonoperational temperature shock

●  14° to 140°F (-10° to 60°C)

Humidity

●  Operating 10% to 90%, noncondensing
●  Non-operating 10% to 95%, noncondensing

Certification and compliance for 6821

●  Regulatory compliance:
◦  CE Markings per directives 2014/30/EU and 2014/35/EU
●  Safety:
◦  UL 60950 Second Edition
◦  CAN/CSA-C22.2 No. 60950 Second Edition
◦  EN 60950 Second Edition (including A11 and A12)
◦  IEC 60950 Second Edition (including A11 and A12)
◦  AS/NZS 60950
●  EMC – Emissions
◦  47CFR Part 15 (CFR 47) Class B
◦  AS/NZS CISPR32:2015 Class B
◦  CISPR 32: 2015_COR1:2016 Class B
◦  EN55032: 2015+AC:2016
◦  ICES003 Class B
◦  EN61000-3-2:2014 and IEC 61000-3-2:2014
◦  EN61000-3-3:2013 and IEC61000-3-3:2013
◦  VCCI Class B
●  EMC – Immunity
◦  EN55024
◦  CISPR24
◦  Armadillo Light
●  Telecom
◦  FCC Part 68 HAC
◦  CS-03-HAC
◦  AS/ACIF S004
◦  AS/ACIF S040
◦  NZ PTC 220
◦  Industry standards: TIA 810
●  Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af

Certification and compliance for 6841, 6851, 6861 and 6871

●  Regulatory compliance:
◦  CE Markings per directives 2004/108/EC and 2014/30/EU
●  Safety:
◦  UL 60950 Second Edition
◦  CAN/CSA-C22.2 No. 60950 Second Edition
◦  EN 60950 Second Edition (including A11 and A12)
◦  IEC 60950 Second Edition (including A11 and A12)
◦  AS/NZS 60950
●  EMC – Emissions
◦  47CFR Part 15 (CFR 47) Class B
◦  AS/NZS CISPR32:2015 Class B
◦  CISPR 32: 2015_COR1:2016 Class B
◦  EN55032: 2015+AC:2016
◦  ICES003 Class B
◦  EN61000-3-2:2014 and IEC 61000-3-2:2014
◦  EN61000-3-3:2013 and IEC61000-3-3:2013
●  EMC – Immunity
◦  EN55024
◦  CISPR24
◦  Armadillo Light
●  Telecom
◦  FCC Part 68 HAC
◦  CS-03-HAC
◦  AS/ACIF S004
◦  AS/ACIF S040
◦  NZ PTC 220
◦  Industry standards: TIA 810 and TIA 920
●  Industry standards: IEEE 802.3 Ethernet, IEEE 802.3af (for CP-6851 only)
●  Radio (for CP-6861 only)
◦  FCC Part 15
◦  EN 300.328
◦  EN 301-489-1
◦  EN 301-489-17
◦  EN 301-489-3
◦  NCC LP0002
◦  EN 301 893
◦  EN 300 330
◦  RSP-100-11
◦  RSS- Gen
◦  RSS-102
◦  RSS-210
◦  RSS-247-2
Drawer Title
Similar Products